Home Online UPS MAX + 2KVA (With Internal Batteries)
MAX + 1KVA (With Internal Batteries) EGP7,000.00
Back to products
MAX + 3KVA (With Internal Batteries) EGP13,615.00

MAX + 2KVA (With Internal Batteries)

EGP12,170.00

MAX + 2KVA (With Internal Batteries) – High Frequency and Double Conversion Online Technology.
High End IGBT Based.
High End Micro Controller Based.
Wide Input Voltage Range
Advanced PFC Technology
Advanced Battery Management
Automatic Battery Charging in UPS Off Mode
Short Circuit and Overload Protection
Smart RS232 Communication with monitoring software
SNMP Card Slot (Optional)
Over Temperature Protection.
EMI / RFI Noise Filter
LCD/LED Display simultaneously
Specially designed to suit Indian Power and Environment Conditions
Generator Compatible (Supplying Sinewave Voltage)
Isolation Transformer (Optional)
Different Output Voltage settings.
Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.
Static Bypass Enable or Disable.
Outlets Programmable and Non Programmable.
Protection from DC Fan failure.
In-built Over Voltage Cut-Off Device.Rated capacity 2KV / 1800 Watts.
input voltage range 118V-295V
input voltage range 160V-295V
frequency 40-70
phase single phase with ground
DC voltage 72V ( 6*7.0 AH battery inside
charge current 0.7-0.8 AMPS
Communication interface RS232.SNMP (optional )
indication LCD Display
noise level less than 50dBA@ 1 meter ( with fan speed )
ups over load / ups short – circuit 110% – 300%
voltage range 208 / 220 / 230 / 240V AC
Frequency range 47 -53HZ or 57 – 63 HZ
WAVEFORM Pure sine wave
transfer time Zero
Crest factor 3:1 Max
short circuit protection 5 cycles turn off inverter, np transfer to bypass, provide alarm (AC mode )

Compare
Add to wishlist
Category: Online UPS
Share
  • Description
  • Reviews (0)
  • Shipping & Delivery
Description

MAX + 2KVA (With Internal Batteries) – High Frequency and Double Conversion Online Technology.
High End IGBT Based.
High End Micro Controller Based.
Wide Input Voltage Range
Advanced PFC Technology
Advanced Battery Management
Automatic Battery Charging in UPS Off Mode
Short Circuit and Overload Protection
Smart RS232 Communication with monitoring software
SNMP Card Slot (Optional)
Over Temperature Protection.
EMI / RFI Noise Filter
LCD/LED Display simultaneously
Specially designed to suit Indian Power and Environment Conditions
Generator Compatible (Supplying Sinewave Voltage)
Isolation Transformer (Optional)
Different Output Voltage settings.
Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.
Static Bypass Enable or Disable.
Outlets Programmable and Non Programmable.
Protection from DC Fan failure.
In-built Over Voltage Cut-Off Device.Rated capacity 2KV / 1800 Watts.
input voltage range 118V-295V
input voltage range 160V-295V
frequency 40-70
phase single phase with ground
DC voltage 72V ( 6*7.0 AH battery inside
charge current 0.7-0.8 AMPS
Communication interface RS232.SNMP (optional )
indication LCD Display
noise level less than 50dBA@ 1 meter ( with fan speed )
ups over load / ups short – circuit 110% – 300%
voltage range 208 / 220 / 230 / 240V AC
Frequency range 47 -53HZ or 57 – 63 HZ
WAVEFORM Pure sine wave
transfer time Zero
Crest factor 3:1 Max
short circuit protection 5 cycles turn off inverter, np transfer to bypass, provide alarm (AC mode )

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “MAX + 2KVA (With Internal Batteries)” Cancel reply

Your email address will not be published. Required fields are marked *

nine + five =

Shipping & Delivery

Related products

Compare

Microtek MAX + SERIES 2KVA

Online UPS
EGP9,690.00
Microtek MAX + SERIES 2KVA - BATTERY DC Voltage 72 V Charge Current 9.5 Amps INPUT Input Voltage Range (Load < 50%) 118 ~ 295 V (± 5 V) Input Voltage range ((Load > 50%)) 160 ~ 295 V (± 5 V) Frequency 40 ~ 70 Hz Phase Single Phase with Ground Power Factor ≥ 0.99 @ full load Communication Interface RS232,SNMP (Optional) Indication LCD Display Noise Level Less than 50dBA @ 1 Meter (With Fan Speed Control) UPS Overload / UPS Short-Circuit 110% / 300% OUTPUT Voltage Range 208 / 220 / 230 / 240 V AC Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Battery Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz THD (Linear Load) ≤ 2% THD (Non Linear Load) ≤ 4% Overload > 110%, 30s turn to Bypass Mode > 150% instant turn to Bypass Crest Factor 3:1 (Max) Short Circuit Protection 5 cycles turn Off Inverter, no transfer to Bypass, provide Alarm (AC Mode), 5 cycles turn Off Inverter, provide Alarm(Battery Mode), Input Fuse blown or Breaker action Waveform Pure Sinewave Transfer time (AC Mode to Battery Mode) (Inverter to Bypass Mode) Zero < 4 ms Efficiency 85%~ 92%
Add to wishlist
Add to cart
Quick view
Compare

Microtek MAX + SERIES 1KVA

Online UPS
EGP6,250.00
Microtek MAX + SERIES 1KVA - DC Voltage 36 V Charge Current 9.5 Amps INPUT Input Voltage Range (Load < 50%) 118 ~ 295 V (± 5 V) Input Voltage range ((Load > 50%)) 160 ~ 295 V (± 5 V) Frequency 40 ~ 70 Hz Phase Single Phase with Ground Power Factor ≥ 0.99 @ full load Communication Interface RS232,SNMP (Optional) Indication LCD Display Noise Level Less than 50dBA @ 1 Meter (With Fan Speed Control) UPS Overload / UPS Short-Circuit 110% / 300% OUTPUT Voltage Range 208 / 220 / 230 / 240 V AC Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Battery Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz THD (Linear Load) ≤ 2% THD (Non Linear Load) ≤ 4% Overload > 110%, 30s turn to Bypass Mode > 150% instant turn to Bypass Crest Factor 3:1 (Max) Short Circuit Protection 5 cycles turn Off Inverter, no transfer to Bypass, provide Alarm (AC Mode), 5 cycles turn Off Inverter, provide Alarm(Battery Mode), Input Fuse blown or Breaker action Waveform Pure Sinewave Transfer time (AC Mode to Battery Mode) (Inverter to Bypass Mode) Zero < 4 ms Efficiency 85%~ 92%
Add to wishlist
Add to cart
Quick view
Compare

MAX + 3KVA (With Internal Batteries)

Online UPS
EGP13,615.00
MAX + 3KVA (With Internal Batteries) - High Frequency and Double Conversion Online Technology. High End IGBT Based. High End Micro Controller Based. Wide Input Voltage Range Advanced PFC Technology Advanced Battery Management Automatic Battery Charging in UPS Off Mode Short Circuit and Overload Protection Smart RS232 Communication with monitoring software SNMP Card Slot (Optional) Over Temperature Protection. EMI / RFI Noise Filter LCD/LED Display simultaneously Specially designed to suit Indian Power and Environment Conditions Generator Compatible (Supplying Sinewave Voltage) Isolation Transformer (Optional) Different Output Voltage settings. Output Frequency fixed at 50Hz or can be synchronized with Input Frequency. Static Bypass Enable or Disable. Outlets Programmable and Non Programmable. Protection from DC Fan failure. In-built Over Voltage Cut-Off Device.Rated Capacity 3KVA / 2700 WATTS input voltage range 118V-295V input voltage range 160V-295V frequency 40-70 phase single phase with ground DC voltage 72V ( 3*7.0 AH battery inside charge current 1.5 AMPS Communication interface RS232.SNMP (optional ) indication LCD Display noise level less than 50dBA@ 1 meter ( with fan speed ) ups over load / ups short - circuit 110% - 300% voltage range 208 / 220 / 230 / 240V AC Frequency range 47 -53HZ or 57 - 63 HZ WAVEFORM Pure sine wave transfer time Zero Crest factor 3:1 Max short circuit protection 5 cycles turn off inverter, np transfer to bypass, provide alarm (AC mode )
Add to wishlist
Add to cart
Quick view
Compare

MAX + 1KVA (With Internal Batteries)

Online UPS
EGP7,000.00
MAX + 1KVA (With Internal Batteries) - High Frequency and Double Conversion Online Technology. High End IGBT Based. High End Micro Controller Based. Wide Input Voltage Range Advanced PFC Technology Advanced Battery Management Automatic Battery Charging in UPS Off Mode Short Circuit and Overload Protection Smart RS232 Communication with monitoring software SNMP Card Slot (Optional) Over Temperature Protection. EMI / RFI Noise Filter LCD/LED Display simultaneously Specially designed to suit Indian Power and Environment Conditions Generator Compatible (Supplying Sinewave Voltage) Isolation Transformer (Optional) Different Output Voltage settings. Output Frequency fixed at 50Hz or can be synchronized with Input Frequency. Static Bypass Enable or Disable. Outlets Programmable and Non Programmable. Protection from DC Fan failure. In-built Over Voltage Cut-Off Device.input voltage range 118V-295V input voltage range 160V-295V frequency 40-70 phase single phase with ground DC voltage 36V ( 3*7.0 AH battery inside charge current 0.7-0.8 AMPS Communication interface RS232.SNMP (optional ) indication LCD Display noise level less than 50dBA@ 1 meter ( with fan speed ) ups over load / ups short - circuit 110% - 300% voltage range 208 / 220 / 230 / 240V AC Frequency range 47 -53HZ or 57 - 63 HZ WAVEFORM Pure sine wave transfer time Zero Crest factor 3:1 Max short circuit protection 5 cycles turn off inverter, np transfer to bypass, provide alarm (AC mode )
Add to wishlist
Add to cart
Quick view
Compare

Microtek MAX + SERIES 3KVA

Online UPS
EGP11,250.00
Microtek MAX + SERIES 3KVA - Rated Capacity 3 KVA / 2700 Watts.BATTERY DC Voltage 72 V Charge Current 9.5 Amps INPUT Input Voltage Range (Load < 50%) 118 ~ 295 V (± 5 V) Input Voltage range ((Load > 50%)) 160 ~ 295 V (± 5 V) Frequency 40 ~ 70 Hz Phase Single Phase with Ground Power Factor ≥ 0.99 @ full load Communication Interface RS232,SNMP (Optional) Indication LCD Display Noise Level Less than 50dBA @ 1 Meter (With Fan Speed Control) UPS Overload / UPS Short-Circuit 110% / 300% OUTPUT Voltage Range 208 / 220 / 230 / 240 V AC Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Battery Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz THD (Linear Load) ≤ 2% THD (Non Linear Load) ≤ 4% Overload > 110%, 30s turn to Bypass Mode > 150% instant turn to Bypass Crest Factor 3:1 (Max) Short Circuit Protection 5 cycles turn Off Inverter, no transfer to Bypass, provide Alarm (AC Mode), 5 cycles turn Off Inverter, provide Alarm(Battery Mode), Input Fuse blown or Breaker action Waveform Pure Sinewave Transfer time (AC Mode to Battery Mode) (Inverter to Bypass Mode) Zero < 4 ms Efficiency 85%~ 92%
Add to wishlist
Add to cart
Quick view
Neons agency 2022 CREATED BY Neons agency. PREMIUM E-COMMERCE SOLUTIONS.
  • Menu
  • Categories
Set your categories menu in Theme Settings -> Header -> Menu -> Mobile menu (categories)
  • Home
  • About
  • SOLAR
    • Inverters
      • On grid
      • Off grid
    • Solar Charger
    • Solar panels
    • Solar water heater
  • UPS
    • Online UPS
    • Line Interactive UPS
    • UPS JUMBO HIGH CAPACITY MODELS
  • Stablilizers
    • A.C. Stabilizers
    • TELEVISION STABILIZER
    • Refrigerator Stabilizers
    • Microtek Mains Stabilizers
  • batteries
  • Contact
  • Clac
Shopping cart
close
Start typing to see posts you are looking for.
Shop
Wishlist
0 items Cart
My account