MAX + 2KVA (With Internal Batteries) – High Frequency and Double Conversion Online Technology.
High End IGBT Based.
High End Micro Controller Based.
Wide Input Voltage Range
Advanced PFC Technology
Advanced Battery Management
Automatic Battery Charging in UPS Off Mode
Short Circuit and Overload Protection
Smart RS232 Communication with monitoring software
SNMP Card Slot (Optional)
Over Temperature Protection.
EMI / RFI Noise Filter
LCD/LED Display simultaneously
Specially designed to suit Indian Power and Environment Conditions
Generator Compatible (Supplying Sinewave Voltage)
Isolation Transformer (Optional)
Different Output Voltage settings.
Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.
Static Bypass Enable or Disable.
Outlets Programmable and Non Programmable.
Protection from DC Fan failure.
In-built Over Voltage Cut-Off Device.Rated capacity 2KV / 1800 Watts.
input voltage range 118V-295V
input voltage range 160V-295V
frequency 40-70
phase single phase with ground
DC voltage 72V ( 6*7.0 AH battery inside
charge current 0.7-0.8 AMPS
Communication interface RS232.SNMP (optional )
indication LCD Display
noise level less than 50dBA@ 1 meter ( with fan speed )
ups over load / ups short – circuit 110% – 300%
voltage range 208 / 220 / 230 / 240V AC
Frequency range 47 -53HZ or 57 – 63 HZ
WAVEFORM Pure sine wave
transfer time Zero
Crest factor 3:1 Max
short circuit protection 5 cycles turn off inverter, np transfer to bypass, provide alarm (AC mode )
MAX + 2KVA (With Internal Batteries)
EGP12,170.00
MAX + 2KVA (With Internal Batteries) – High Frequency and Double Conversion Online Technology.
High End IGBT Based.
High End Micro Controller Based.
Wide Input Voltage Range
Advanced PFC Technology
Advanced Battery Management
Automatic Battery Charging in UPS Off Mode
Short Circuit and Overload Protection
Smart RS232 Communication with monitoring software
SNMP Card Slot (Optional)
Over Temperature Protection.
EMI / RFI Noise Filter
LCD/LED Display simultaneously
Specially designed to suit Indian Power and Environment Conditions
Generator Compatible (Supplying Sinewave Voltage)
Isolation Transformer (Optional)
Different Output Voltage settings.
Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.
Static Bypass Enable or Disable.
Outlets Programmable and Non Programmable.
Protection from DC Fan failure.
In-built Over Voltage Cut-Off Device.Rated capacity 2KV / 1800 Watts.
input voltage range 118V-295V
input voltage range 160V-295V
frequency 40-70
phase single phase with ground
DC voltage 72V ( 6*7.0 AH battery inside
charge current 0.7-0.8 AMPS
Communication interface RS232.SNMP (optional )
indication LCD Display
noise level less than 50dBA@ 1 meter ( with fan speed )
ups over load / ups short – circuit 110% – 300%
voltage range 208 / 220 / 230 / 240V AC
Frequency range 47 -53HZ or 57 – 63 HZ
WAVEFORM Pure sine wave
transfer time Zero
Crest factor 3:1 Max
short circuit protection 5 cycles turn off inverter, np transfer to bypass, provide alarm (AC mode )
Reviews
There are no reviews yet.