Showing 25–36 of 42 results

Microtek MAX + SERIES 1KVA

EGP6,250.00
Microtek MAX + SERIES 1KVA - DC Voltage 36 V Charge Current 9.5 Amps INPUT Input Voltage Range (Load < 50%) 118 ~ 295 V (± 5 V) Input Voltage range ((Load > 50%)) 160 ~ 295 V (± 5 V) Frequency 40 ~ 70 Hz Phase Single Phase with Ground Power Factor ≥ 0.99 @ full load Communication Interface RS232,SNMP (Optional) Indication LCD Display Noise Level Less than 50dBA @ 1 Meter (With Fan Speed Control) UPS Overload / UPS Short-Circuit 110% / 300% OUTPUT Voltage Range 208 / 220 / 230 / 240 V AC Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Battery Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz THD (Linear Load) ≤ 2% THD (Non Linear Load) ≤ 4% Overload > 110%, 30s turn to Bypass Mode > 150% instant turn to Bypass Crest Factor 3:1 (Max) Short Circuit Protection 5 cycles turn Off Inverter, no transfer to Bypass, provide Alarm (AC Mode), 5 cycles turn Off Inverter, provide Alarm(Battery Mode), Input Fuse blown or Breaker action Waveform Pure Sinewave Transfer time (AC Mode to Battery Mode) (Inverter to Bypass Mode) Zero < 4 ms Efficiency 85%~ 92%

Microtek MAX + SERIES 2KVA

EGP9,690.00
Microtek MAX + SERIES 2KVA - BATTERY DC Voltage 72 V Charge Current 9.5 Amps INPUT Input Voltage Range (Load < 50%) 118 ~ 295 V (± 5 V) Input Voltage range ((Load > 50%)) 160 ~ 295 V (± 5 V) Frequency 40 ~ 70 Hz Phase Single Phase with Ground Power Factor ≥ 0.99 @ full load Communication Interface RS232,SNMP (Optional) Indication LCD Display Noise Level Less than 50dBA @ 1 Meter (With Fan Speed Control) UPS Overload / UPS Short-Circuit 110% / 300% OUTPUT Voltage Range 208 / 220 / 230 / 240 V AC Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Battery Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz THD (Linear Load) ≤ 2% THD (Non Linear Load) ≤ 4% Overload > 110%, 30s turn to Bypass Mode > 150% instant turn to Bypass Crest Factor 3:1 (Max) Short Circuit Protection 5 cycles turn Off Inverter, no transfer to Bypass, provide Alarm (AC Mode), 5 cycles turn Off Inverter, provide Alarm(Battery Mode), Input Fuse blown or Breaker action Waveform Pure Sinewave Transfer time (AC Mode to Battery Mode) (Inverter to Bypass Mode) Zero < 4 ms Efficiency 85%~ 92%

Microtek MAX + SERIES 3KVA

EGP11,250.00
Microtek MAX + SERIES 3KVA - Rated Capacity 3 KVA / 2700 Watts.BATTERY DC Voltage 72 V Charge Current 9.5 Amps INPUT Input Voltage Range (Load < 50%) 118 ~ 295 V (± 5 V) Input Voltage range ((Load > 50%)) 160 ~ 295 V (± 5 V) Frequency 40 ~ 70 Hz Phase Single Phase with Ground Power Factor ≥ 0.99 @ full load Communication Interface RS232,SNMP (Optional) Indication LCD Display Noise Level Less than 50dBA @ 1 Meter (With Fan Speed Control) UPS Overload / UPS Short-Circuit 110% / 300% OUTPUT Voltage Range 208 / 220 / 230 / 240 V AC Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz Frequency Range (Battery Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz THD (Linear Load) ≤ 2% THD (Non Linear Load) ≤ 4% Overload > 110%, 30s turn to Bypass Mode > 150% instant turn to Bypass Crest Factor 3:1 (Max) Short Circuit Protection 5 cycles turn Off Inverter, no transfer to Bypass, provide Alarm (AC Mode), 5 cycles turn Off Inverter, provide Alarm(Battery Mode), Input Fuse blown or Breaker action Waveform Pure Sinewave Transfer time (AC Mode to Battery Mode) (Inverter to Bypass Mode) Zero < 4 ms Efficiency 85%~ 92%

Microtek Sinewave UPS XP SW 2300

EGP5,970.00
Microtek Sinewave UPS XP SW 2300 - input voltage standard range 90V - 300V input voltage narrow range 180V - 260V output voltage mains mode same as input output voltage ups mode 200V -260V output waveform mains mode same as input output waveform ups mode tpzi waveform swich over from mains to ups and ups to mains ( Automatic ) Design micro controller based design battery charging current 10% of the rated battery current in AH ups overload / ups short - circuit 110% - 300%

Microtek Trolley For Double Battery

EGP1,050.00
Microtek Trolley For Double Battery - Weight – 12.400kg - Dimensions (L W H) – 633x310x432

Microtek Trolley For Single Battery

EGP650.00
Microtek Trolley For Single Battery - Weight – 6.200kg - Dimensions (L W H) – 640x189x432

Microtek UPS JM SW 4000/48V

EGP10,687.00
Microtek UPS JM SW 4000/48V - Rated Capacity 3.7 KVA Output Power 2960 Watts Battery 4 Battery System (48 VDC) Waveform Pure Sinewave INPUT Input Voltage (Standard range) 110 V ~ 280 V Input Voltage (Narrow range) 180V ~ 265 V OUTPUT Output Voltage (Mains Mode) Same as Input Output Voltage (UPS Mode) 180~230 V (± 10V) Output Waveform (Mains Mode) Same as Input Output Waveform (UPS Mode) Pure Sinewave CHANGEOVER Switchover from Mains to UPS and UPS to Mains Automatic UPS Transfer Time ≤ 15 msec. TECHNOLOGY Design Micro Controller Based Design Battery Charging Current 17 Amps ± 3 Amps UPS Overload / UPS Short-circuit ≥110% / ≥ 300% Browns on Mains Voltage 100V ± 10V Efficiency (Battery Mode) > 80% Auto Reset Feature Yes Input DC Range 42 V ~ 56.8 V Air Conditioner TDR Upto 1.0 Tons

Microtek UPS JM SW 5500/48V

EGP21,375.00
Microtek UPS JM SW 5500/48V - Rated Capacity 5.2 KVA Output Power 4160 Watts Battery 4 Battery System (48 VDC) Waveform Pure Sinewave INPUT Input Voltage (Standard range) 110 V ~ 280 V Input Voltage (Narrow range) 180V ~ 265 V OUTPUT Output Voltage (Mains Mode) Same as Input Output Voltage (UPS Mode) 180~230 V (± 10V) Output Waveform (Mains Mode) Same as Input Output Waveform (UPS Mode) Pure Sinewave CHANGEOVER Switchover from Mains to UPS and UPS to Mains Automatic UPS Transfer Time ≤ 15 msec. TECHNOLOGY Design Micro Controller Based Design Battery Charging Current 17 Amps ± 3 Amps UPS Overload / UPS Short-circuit ≥110% / ≥ 300% Browns on Mains Voltage 100V ± 10V Efficiency (Battery Mode) > 80% Auto Reset Feature Yes Input DC Range 42 V ~ 56.8 V Air Conditioner TDR Upto 2.0 Tons

Microtek UPS LEGEND 1000

EGP2,500.00
Microtek UPS LEGEND 1000 - input voltage range 140V - 300V AC Frequency 50HZ Output voltage 230V transfer time typical 4 - 8ms wave form ( battery mode ) modified sine wave charging time 6 - 8 hours recover to 90% capacity battery rating smf 12V /7AH*2 Nos

Microtek UPS LEGEND 1000

EGP2,500.00
Microtek UPS LEGEND 1000 – input voltage range 140V – 300V AC Frequency 50HZ Output voltage 230V transfer time typical

Microtek UPS LEGEND 650

EGP1,315.00
Microtek UPS LEGEND 650 - input voltage range 140V - 300V AC Frequency 50HZ Output voltage 230Vtransfer time typical 4 - 8ms wave form ( battery mode ) modified sine wave charging time 6 hours recover to 90% capacity battery rating smf 12V /7AH

Microtek UPS LEGEND 650

EGP1,315.00
Microtek UPS LEGEND 650 – input voltage range 140V – 300V AC Frequency 50HZ Output voltage 230Vtransfer time typical 4